ELSO Technologies Sdn Bhd
8E, First Floor,
Jalan Tun Dr. Awang,
Bukit Jambul,
11900 Bayan Lepas,
Penang, Malaysia.
+604-6301166
+604-6301167
+604-6301168
sales@elsotech.com

Mr Kwang (General Manager)
+6016-422 8644
 
+60164228644

Johor Branch
Lake View Apartment,
Jalan Austin Perdana 1,
Taman Austin Perdana,
81100 Johor Bahru,
Johor, Malaysia.

Chong CW (Sales Manager)
+6012-4767747
cwchong@elsotech.com

Selangor Branch
Puchong, Selangor.

Glenys Teoh (Sales Manager)
+6018-2810168
glenysteoh@elsotech.com

East Malaysia Branch
Lot 35, Lot 5277,
Lorong 9C1, Jalan Kapor,
93150 Kuching,
Sarawak, Malaysia.

Clement Lau (Sales Engineer)
+6019-8497663
clementlau@elsotech.com

ELSO Technologies Pte Ltd
Singapore Branch

1 Coleman Street
#10-06 The Adelphi
179803 Singapore.

Chew Peng Seng  (Sales Manager)
+65 9663 8176
pengseng@elsotech.com

563 Bayard-Alpert Gauge Tube

Previous 10 / 17 Next

563 Bayard-Alpert Gauge Tube Vacuum Measurement Agilent Technologies


The Agilent 563 Bayard-Alpert hot-cathode ionization gauge tubes employ a heated filament for the source of electrons. The gauge tube offers superior performance over a pressure range of 2 x 10-10 to 1 x 10-3 torr. The inside of the glass body is platinum-coated, shielding the gauge elements from electrostatic charge at low pressures while draining off the static charge that can build up at high pressure. A reference gauge tube is also available, sealed off at ≤ 5 x 10-6 torr for use in testing a gauge controller.

Sensitivity
10 (Torr)-1 (mbar)-1 (typical)
Exact measurement available through Agilent STARRS program.
Contact Agilent for details
Operating ratings
 •   0 VDC (collector)
 •   + 180 VDC to ground (grid)
 •   + 30 VDC to ground
 •   5 VAC nominal (filament)
X-Ray limit
2 x 10-10 Torr, (2.6 x 10-10 mbar)
Operating pressure
2 x 10-10 Torr to 1 x 10-3 Torr?
(2.7 x 10-10 mbar to 1 x 10-3 mbar)
 



563 Ionization tube with thoria-coated iridium filament K2466301 1 in. Glass tubulation 0.5 (1.0) K2466302 1 in. Kovar tubulation 0.5 (1.0) K2466304 ¾ in. Glass tubulation 0.5 (1.0) K2466305 ¾ in. Kovar tubulation 0.5 (1.0) K2466306 NW25 KF 0.5 (1.0) K2466311 NW40 KF 1.0 (2.0) K2466303 2.75 in. CFF 1.0 (2.0) 563 reference ionization tube with thoria-coated K2466307 – 0.5 (1.0) iridium filament (sealed off at ≤5 x 10-6 Torr)