ELSO Technologies Sdn Bhd
8E, First Floor,
Jalan Tun Dr. Awang,
Bukit Jambul,
11900 Bayan Lepas,
Penang, Malaysia.
+604-6301166
+604-6301167
+604-6301168
sales@elsotech.com

Mr Kwang (General Manager)
+6016-422 8644
 
+60164228644

Johor Branch
Lake View Apartment,
Jalan Austin Perdana 1,
Taman Austin Perdana,
81100 Johor Bahru,
Johor, Malaysia.

Chong CW (Sales Manager)
+6012-4767747
cwchong@elsotech.com

Selangor Branch
Puchong, Selangor.

Glenys Teoh (Sales Manager)
+6018-2810168
glenysteoh@elsotech.com

East Malaysia Branch
Lot 35, Lot 5277,
Lorong 9C1, Jalan Kapor,
93150 Kuching,
Sarawak, Malaysia.

Clement Lau (Sales Engineer)
+6019-8497663
clementlau@elsotech.com

ELSO Technologies Pte Ltd
Singapore Branch

1 Coleman Street
#10-06 The Adelphi
179803 Singapore.

Chew Peng Seng  (Sales Manager)
+65 9663 8176
pengseng@elsotech.com

N7553A Electronic Calibration Module (ECal), DC-14 GHz, 2-Port

Previous 3 / 69 Next

N7553A Electronic Calibration Module (ECal), DC-14 GHz, 2-Port  RF and Microwave Electromechanical Switches  Keysight Technologies


Key Features & Specifications

  • Frequency coverage from DC to 14 GHz
  • Supports Type N and 3.5 mm connectors
  • Smaller, lighter 2-port ECal module
  • Zero wait time for faster calibration
  • Convenience of ECal with the performance of an economy mechanical kit 


     

Description

The N7553A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products. 

The N7553A supports Keysight’s , PNA-X, PNA, ENA, and PXI vector network analyzers, and FieldFox handheld analyzers. The N7553A is a 2-port ECal module that supports 3.5 mm connectors or Type N connectors. As a value-line product, it makes it cost effective to replace the N7553A than to have it recertified.

The firmware installed on the instrument is used to control the calibration module, making it a fully integrated solution. The calibration code on the instrument communicates via a USB 2.0 micro-interface and simplifies the calibration to a single connection for a full two-port calibrated measurement. 


Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Messages*  
   

Switch to Mobile Version
available in