ELSO Technologies Sdn Bhd
8E, First Floor,
Jalan Tun Dr. Awang,
Bukit Jambul,
11900 Bayan Lepas,
Penang, Malaysia.
+604-6301166
+604-6301167
+604-6301168
sales@elsotech.com

Mr Loo (General Manager)
+6012-478 5533

Mr Kwang (Sales Manager)
+6016-422 8644
 
+60164228644

Johor Branch
Lake View Apartment,
Jalan Austin Perdana 1,
Taman Austin Perdana,
81100 Johor Bahru,
Johor, Malaysia.

Chong CW (Sales Manager)
+6012-4767747
cwchong@elsotech.com

Selangor Branch
87, Jalan Tasik Prima 4/5,
Taman Tasik Prima,
47150 Puchong,
Selangor, Malaysia.

Glenys Teoh (Sales Manager)
+6018-2810168
glenysteoh@elsotech.com

East Malaysia Branch
Lot 35, Lot 5277,
Lorong 9C1, Jalan Kapor,
93150 Kuching,
Sarawak, Malaysia.

Clement Lau (Sales Engineer)
+6019-8497663
clementlau@elsotech.com

ELSO Technologies Pte Ltd
Singapore Branch

1 Coleman Street
#10-06 The Adelphi
179803 Singapore.

Chew Peng Seng  (Sales Manager)
+65 9663 8176
pengseng@elsotech.com

Haematokrit 200

Previous 1 / 3 Next

Haematokrit 200 Centrifuges Hettich


 

 

The HAEMATOKRIT 200 is a compact and efficient centrifuge for the determination of the volume fraction of the erythrocytes in the blood.

In neonatology, the hematocrit centrifuge is also used for plasma collection for the photometric determination of the bilirubin content in the blood of neonates.

The powerful centrifuge separates samples in minutes: With a maximum centrifugal acceleration of 16.060 xg, this hematocrit centrifuge requires less than seven minutes until the red blood cells reach their maximum packing density or until cell-free plasma is available for further examinations.

You can centrifuge 24 capillary tubes per barrel. The segmented rotor of the centrifuge offers each capillary its own chamber. This has the advantage that, in the event of glass breakage, no further capillary tubes are damaged as a result of a chain reaction. Glass splitter and blood of the affected capillary tube are collected by a cushioning dish located at the outer edge of each segment. It also serves as a support for the capillary tubes, is easy to clean and replace.

After sedimentation, you can read the hematocrit values ​​with the aid of the rotor cover, which simultaneously serves as an evaluation disk. Do not remove the capillaries. This saves time and provides additional security.

 

PRODUCT DETAILS

  • Max. Capacity: in the hematocrit rotor:
    24 standard capillaries
  • Max. Speed:
    13,000 min -1
  • Max. RCF:
    16.060
  • Dimensions (H x W x D):
    228 x 261 x 353 mm
  • Mass:
    Approx. 10 kg
  • Cooling:
    Air cooling
  • Rotors:
    Hematocritrotor for 24 standard capillaries, max. RCF 16.060 - Order no. 2076
  •  
    Plate rotor for 20 capillaries for Buffy Coat analysis, max. RCF 16.060 - Order no. 2056
  •  
    HAEMATOKRIT 200, without rotor, Order No. 1801